N1C 2000VA 230V LITHIUM UPS-10Y WARRANTY

by
N1 CRITICAL TECHNOLOGIES INC.
PCN#
1925AT
MFG#
N1C.L2000G
$2,264.75
cps

Extended & Accidental Damage Protection Plans Available Details

  Free Shipping
Estimated Shipment:

Calculating Shipping

Product Highlights:
  • 2U Rack/Tower
  • 14 Minute Stand
  • by

Show more

Product Condition: New and Factory Fresh
Limited Warranty10 Year
Shipping Weight: 44 lbs.
N1C N1C.L2000G 2kVA Rack/Tower UPS
Tech Specs
Specifications

Manufacturer

N1C Technologies, Inc.

Manufacturer Part Number

N1C.L2000G

Manufacturer Website Address

http://www.n1critical.com

Brand Name

N1C

Product Series

L

Product Model

N1C.L2000G

Product Name

N1C.L2000G 2kVA Rack/Tower UPS

Marketing Information

Life Span:

The average life span of a VRLA battery is 4-6 years in ideal conditions. N1C Li-Ion battery life span is 10-15 year in nearly all conditions. Long life
batteries reduce the burden and cost of down time and maintenance.

High Power Density:

Lithium Ion batteries have over 5 times the Energy density and take up about 1/3 the space of a VRLA based solution that delivers the same power. This means more power in the same or smaller footprint.

Charge and Recharge Efficiency:

N1C Lithium Ion batteries can be charged/ discharged over 1000 times versus 200-400 charges/ discharges for standard VRLA batteries. N1C Lithium UPS units include built in chargers capable of 1-hour recharge times, compared to 4-10 hour recharge times of VRLA battery UPS systems.

Smaller Footprint:

A smaller footprint translates to reduced cooling requirements as well as about a two thirds reduction in weight. This offers the installation flexibility needed by many IT departments.

Environmentally Friendly:

Other than the obvious, that Lithium Ion batteries do not use Lead, there are many other "green" benefits to Lithium. Lithium batteries require less charging time and power, need to be replaced less often, and take less energy to produce and transport.

Heat Tolerant:

L-Series UPS units can withstand working temperatures up to 140 ?F. Where VRLA battery life is reduced by half for every 10 ?F over 70F, Li-Ion battery life is unaffected.

Product Type

Double Conversion Online UPS
Technical Information

Plug/Connector Type

NEMA L6-20P

Receptacle Type

  • IEC 60320 C19
  • IEC 60320 C13

Receptacle Detail

  • 1 x IEC 60320 C19
  • 6 x IEC 60320 C13

Overload Protection

Yes

Transfer Time

0 ns

Phase

Single Phase

Application/Usage

  • Rack Device
  • Computer Room
  • Data Center
  • POS Terminal
  • Network Router
  • Network Hub
  • Network Device
  • Commercial
  • Precision Instrument
Power Description

Load Capacity

2000 VA/1800 W

Input Voltage

230 V AC

Input Voltage Range

208 V - 240 V

Output Voltage

  • 208 V AC
  • 220 V AC
  • 230 V AC
  • 240 V AC

Input Frequency

60 Hz

Output Frequency

60 Hz

Waveform Type

Sine Wave
Management

Network Management

SNMP

Alarm

  • Low Battery
  • Abnormal Input Voltage
  • UPS Failure
Interfaces/Ports

EPO Port

Yes

USB (HID Compliant) Port

Yes
Battery Information

DC System Voltage

48 V DC

Battery Chemistry

Lithium-Ion (LiFePO4)

Battery Capacity

10000 mAh

Backup/Run Time (Full Load)

14 Minute

Backup/Run Time (Half Load)

28 Minute
Environmental Conditions

Maximum Operating Temperature

140°F (60°C)
Physical Characteristics

Height

3.4"

Width

17.2"

Depth

22.6"

Rack Height

2U

Form Factor

Rack/Tower

Weight (Approximate)

44 lb
Miscellaneous

Package Contents

  • N1C.L2000G 2kVA Rack/Tower UPS
  • Tower Feet
  • Rails
Warranty

Limited Warranty

10 Year